ORVALDI VT 1-2-3KL on-line TOWER

Seria: Long runtime Inverter

When the failure of mains is likely to be long and your load is low, th eORVALDI Inverter (in UPS function) is good solution.  ORVALDI VT 1 – 2 - 3KL on-line works in the true on-line topology. Double conversion voltage output voltage ensures stability and safety critical applications, it secures your data loss from power failure, surge, and sags. Wide input voltage range allows you to restrict the use of the battery, which in turn increases their lifespan.

Producător: ORVALDI
Codul produsului: VT 1-2-3KL
ORVALDI VT 1-2-3KL on-line TOWER
ORVALDI VT 1-2-3KL on-line TOWER
ORVALDI VT 1-2-3KL on-line TOWER

Caracteristică:

  • household electronics,
  • alarm system,
  • telecommunication systems, VOIP,
  • fiscal devices,
  • servers and computer networks (passive and active PFC),
  • measuring and control devices,
  • medical equipment,

Lista aplicațiilor:

  • household electronics,
  • alarm system,
  • telecommunication systems, VOIP,
  • fiscal devices,
  • servers and computer networks (passive and active PFC),
  • measuring and control devices,
  • medical equipment,

 

Product features:

  • True double-conversion online UPS,
  • Output power factor 0.9,
  • Wide input voltage range (160-300V AC),
  • User-friendly LCD,
  • Switching time 0ms,
  • 50Hz/60Hz frequency converter mode,
  • Tower design,
  • Programmable power management outlets,
  • ECO operation for energy saving,
  • Emergency power off function (EPO),
  • Hot-swappable battery,
  • Multiple communication RS232/USB, option SNMP/AS400,
  • Version for a long time battery operation available,

Date tehnice:

Model ORVALDI VT1KL on-line ORVALDI VT2KL on-line ORVALDI VT3KL on-line
Part no VWPP1K VWPP2K VWPP3K
Capacity 1000V A/900W 2000V A/1800W 3000V A/2700W
INPUT
Voltage Range 120-300VAC @ 50% of load, 180-280VAC @ 100% of load
Frequency Range 40~70Hz
Power Factor ≥0.99 @ 100% of load
OUTPUT
Output Voltage 200/208/220/230/240VAC (programmable)
AC Voltage Regulation (Batt. Mode) ±1%
Frequency Range (Synchronized Range) 47~53Hz lub 57~63Hz
Frequency Range (Batt. Mode) 50Hz lub 60Hz ± 0.5%
Waveform (Batt. Mode) Pure sinewave
Current Crest Ratio 3:1
Harmonic Distortion ≤ 3% THD (Linear Load), ≤ 6% (Non-Linear load)
Transfer time (AC Mode to Batt. Mode) 0ms
Transfer Time (Inverter to Bypass) 4ms
EFFICIENCY
AC Mode 88% 89% 90%
Battery Mode 83% 85% 88%
Charging Current (Max.) 6A max
Charging Voltage 27,4VDC ± 1% 54.7VDC ±1 % 82.1VDC ±1%
INDICATORS UPS status, Load level, Battery level, Input/Output voltage, Discharge timer and Fault conditions
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
PHYSICAL
Dimension, DxWxH (mm) 282 x 145 x 220 397 x 145 x 220 421 x 190 x 318
Net Weight (kgs) 9.8 17 27.6
ENVIRONMENT 20-90 % at 0- 40°C (Non-condensing)
Noise Level Less than 50dB @ 1 Meter
MANAGEMENT
RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC
Optional SNMP/AS 400 Power management from SNMP manager and web browser