Offering high efficiency and overload capability, +Power is a truly modular UPS system which can easily scales in 20kW or 30kW increments up to 210kW. Modular design is applied in power module, STS module and battery module. It will simplify maintenance and replacement with low MTTR.
High efficiency online double conversion technology
Data center
Telco centers
sensitive systems
Medical eguipment
Laboratory devices
Model | +Power 30U -90HV |
+Power 42U -120HV |
+Power 30U +Power 30U |
+Power 30U +Power 30U |
+Power 42U -200-20KHV |
+Power 42U -210HV |
+Power 42U -300HV |
PHASE | 3-phase in/3-phase out | ||||||
CABINET CAPACITY* | 90 KW | 120 KW | 120 KW or 80 KW |
180 KW or 120 KW |
200 KW | 210 KW | 300 KW |
BATTERY TYPE | Built-in Battery | External Battery | |||||
ONE POWER MODULE CAPACITY | 30KVA / 30KW | 30KVA / 30KW or 20KVA / 20KW | 20KW | 30KVA / 30KW | |||
MAX. POWER MODULE NO. | 3 | 4 | 4 | 6 | 10 | 8 | 10 |
MAX. BATTERY SET NO.** | 3 | 5 | - | - | - | - | - |
INPUT | |||||||
Nominal Voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | ||||||
Voltage Range | 305 ~ 478 VAC at 100% load; 208 ~ 304VAC at <70% load | ||||||
Nominal Frequency | 50/60Hz (Auto Sensing) | ||||||
Frequency Range | 40Hz ~70Hz | ||||||
Power Factor | > 0.99 @ 100% Load , >0.98 @ 50% Load | ||||||
Harmonic Distortion (THDi) | < 3% @ 100% load | ||||||
OUTPUT | |||||||
Nominal Voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | ||||||
Voltage Regulation (Steady state) | ≦ ± 1% Typical (balanced load) ; ≦ ± 2% Typical (unbalanced load) | ||||||
Nominal Frequency | 50/60Hz | ||||||
Frequency Range (Synchronized) | 46Hz ~ 54Hz or 56Hz ~ 64Hz | ||||||
Overload Capability | 1 hour for 110%, 10 mins for 125%,; 1 min for 150%, 200ms for >150% | ||||||
Harmonic Distortion | ≦2% THD (Linear Load) ; ≦ 4% THD (Non-linear Load) | ||||||
Efficiency | Up to 94.5% | ||||||
BATTERY / CHARGER | |||||||
Nominal Voltage | +/- 216V (12V x 36 pcs) | ||||||
Maximum Voltage | +/- 240V (12V x 40 pcs) | ||||||
Minimum Voltage | +/- 192V (12V x 32 pcs) | ||||||
Float Charging Voltage | 2.25V / Cell | ||||||
Boost Charging Voltage | 2.35V / Cell | ||||||
Temperature Compensation | Yes | ||||||
Maximum Charging Current (Per Power Module) |
8A | 8A for 30KW power module 6A for 20KW power module |
6A | 8A | |||
PHYSICAL | |||||||
Cabinet Dimension (D x W x H) mm | 1100 x 600 x 1475 | 1100 x 600 x 2010 | 1100 x 600 x 1475 | 1100 x 600 x 1475 | 1100 x 600 x 2010 | ||
Net Weight (Kg) | 675 | 932 | 335 or 333 | 437.5 or 434.5 | 611 | 549 | 620 |
ENVIRONMENT | |||||||
Operating Temperature | 0 ~ 40°C | ||||||
Relative Humidity | 0 ~ 95% non-condensing | ||||||
Altitude | <1000m for Nominal power | ||||||
IP Class | IP 20 | ||||||
MANAGEMENT | |||||||
Smart RS-232/USB | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, and MAC | ||||||
Optional SNMP | Power management from SNMP manager and web browser | ||||||
STANDARDS | |||||||
Safety | IEC/EN 60950-1; IEC/EN 62040-1 | ||||||
EMC | IEC/EN 62040-2 Category C3 |
**When temperature is above 30℃, the output power factor will be de-rated, 0.9 at 31℃~35℃ and 0.8 at 36℃~40℃. |
** One battery module contains 10 pcs of 12V/7Ah or 12/9Ah sealed lead acid batteries in one tray. One complete battery set contains 4 battery modules. ***If the UPS is installed or used in a place where the altitude is more than 1000m, the output power must be derated one percent per 100m. |
Product specifications are subject to change without further notice. |